Second-Degree Atrioventricular (AV) Block, Mobitz Type 2
Constant PP interval and PR interval, with sudden dropped beat (non-conducted P wave, arrow). Usually due to disorder of His-Purkinje system and often progresses to complete AV block, frequently with an unreliable escape rhythm.