  • The scope of this article is limited to the testing of blood, urine and mucosal samples.
  • The most common point-of-care tests used for self-monitoring are glucose tests used for monitoring the treatment of diabetes and INR tests used for monitoring warfarin treatment.
  • Tests to diagnose diseases or to assess fertility, for instance, by monitoring hormone levels or phases of the menstrual cycle, are offered at an ever-increasing rate.
  • Factors associated with sampling and, therefore, sample quality form a significant risk to the reliability of such tests.
  • Approximate detection limits, false positive and negative results and the possibility of inaccurate interpreting of even correct results undermine the value of such tests.
  • Instructions for the use of such tests commonly include contacting a doctor or having laboratory tests taken ultimately regardless of the results.
  • Drawing the wrong conclusions from a self-test, and the consequent failure to diagnose a disease appropriately, pose an actual risk to the patient's health.

General remarks

  • Check the national legislation for locally relevant regulations.
  • The EU IVD Regulation 2017/746 http://eur-lex.europa.eu/eli/reg/2017/746/oj/eng groups medical devices and tests for in vitro diagnosis into point-of-care tests for self-testing and those for professional use.
  • Health care professionals use the term point-of-care testing (POC), and those performing such tests have training in health care.
  • When patients do point-of-care tests using methods intended for self-testing, this is usually called home- or self-testing or self-monitoring.
  • In practice, so-called home tests may be the same as point-of-care tests for professional use, but approving a test for non-professional use requires showing its functionality in the intended use environment, i.e. in the hands of lay people.
  • Home tests must bear CE-marking showing conformity to the requirements and next to it the four-number code of the inspection body that evaluated the product (notified body).
  • The principle covering point-of-care testing in health care is that there must be a clinical need for the test and that the result must help with making a treatment decision. This requires similar reliability as achieved with tests performed in laboratory conditions, which self-testing cannot achieve.
  • Limited reliability and varying indications make the usability of many tests more uncertain.
  • Pregnancy tests are an example of functional, established tests; pregnancy is highly likely to be confirmed by a home test at first.
  • Nevertheless, home tests often include guidance to the effect that negative results will not rule out the tested condition and that even positive results should be confirmed in health care.
  • The need for treatment should be assessed by a professional, and diagnosis cannot depend on self-testing, either.

Methodology

  • A significant proportion of home blood, urine and mucosal tests are based on immunochemical reactions where specific antibodies bind to an antigen and the colour-labelled antigen-antibody complex attaches to a certain place in the pad, forming a “positive” line (picture 1). The result is qualitative or semiquantitative.
  • The structure detected in the sample may also be an antibody (tests for coeliac disease, HIV or syphilis, for example).
  • A typical simple test pad is a plastic cassette with a separate well for the sample and a reactive area where the sample migrates in the matrix. The term lateral flow (LF) test is often used for this.
  • The supplies must be at the right (usually room) temperature, and the reaction, or the result, must be read at the given time, not earlier or later, because results based on colour reaction, in particular, may change with time.
  • Interpreting a line on a strip is often difficult; therefore, professionals using such tests are required to have done a sufficient number of tests to ensure sufficient skills.

Blood tests

  • Finger prick tests (i.e. capillary blood tests) are available for coeliac disease, borreliosis, ‘iron deficiency', or to test ferritin, PSA, CRP or vitamin D, for example.
  • Glucose or INR tests are not discussed here because people with diabetes and those on warfarin are trained for doing the tests in health care.
    • The kits typically include a lancet for finger prick or incision and a small capillary tube (dropper) for placing the blood drop onto the test strip.
    • The usability of such equipment varies, and getting results may be uncertain. Use of plastic droppers, in particular, may require significant dexterity.
    • The reproducibility of results from an individual and their level compared with results obtained with methods used in central laboratories vary greatly.
  • Package inserts do not usually describe the capacity of home tests regarding aspects such as measuring range, sensitivity, specificity, reproducibility or sources of error as is required from laboratory methods. The probably large variation in sample composition compared with intravenous samples probably explains at least some of the differences in results - the technique of taking a finger prick sample is not too easy for professionals, either.
  • If a prick (or, more appropriately, incision) made with the lancet remains too superficial and the amount of blood obtained too small, the tester will be tempted to squeeze the fingertip to obtain a sufficient blood drop. This will result in too much tissue fluid in the sample, and squeezing may break up cells, which may also affect the results.
    • The level of haemoglobin, for example, tested from a fingertip may appear much lower if the sample is diluted by tissue fluid.
  • It is often instructed that hands should be washed with soap and water before the finger prick; this is often sufficient as such.
    • However, failure to dry the skin properly or some liquid or cleansing agent ending up in the sample may affect the tests.
    • Similarly, residues of sugary products on the fingers may give false results in glucose tests.
  • Quality monitoring cannot be done at home, and control of results will only depend on the internal control line on the test strip.
    • The control line just shows that the labelled antibody attaches to the solid antibody on the test strip.
    • The functionality or promised sensitivity of the test batch cannot be confirmed.

Coeliac disease test

  • The coeliac disease test shows IgA antibodies to tissue transglutaminase as is appropriate when screening for coeliac disease, and concentrations exceeding 10 IU/ml give positive results.
  • However, the test does not take into account IgA deficiency, which is relatively common in patients with coeliac disease. Negative results are therefore only suggestive because IgG type antibodies cannot be shown in people not producing IgA.

Ferritin test

  • There are several alternatives for ferritin testing. One manufacturer misleadingly calls the test an “anaemia test” and describes it as measuring iron deficiency anaemia. However, the test is not a haemoglobin test but a ferritin test providing positive results if the ferritin level is below 20 ng/ml (the unit used by laboratories is μg/l).
  • If the test result is “positive” and the ferritin level low, the patient's overall situation should be assessed, examining any iron deficiency or anaemia and the cause for these. If the test was done to investigate symptoms of unknown cause, further investigations are probably necessary regardless of the result. Even if the ferritin level appears normal, this does not mean that there is no disease, and the cause of the symptoms must be investigated anyway.

Vitamin D test

  • According to the description of one test, the test analyses a blood drop to see if its vitamin D concentration is sufficient. The result is interpreted based on the intensity of the line colour on the scale ‘deficiency - insufficient - sufficient'.
  • Assessing the intensity of a colour reaction is highly demanding and very subjective in practice.
  • Another test promises to give results based on DNA analysis from buccal mucosa, and the sample is sent to a laboratory for analysis. Naturally, a DNA test cannot be used to assess serum vitamin D levels directly.
  • In laboratory conditions, too, different vitamin D test methods give different results, and the sample tube material, for instance, may cause variation. Reproducible and successful measurement by a home test therefore appears challenging.

CRP test

  • The test shows whether the CRP level is < 8 mg/l or elevated. According to the instructions, if the level is elevated the person may have incipient or current infection and should contact a doctor. The instructions additionally state that a level exceeding 100 mg/l suggests a severe infection and a doctor should be contacted without delay.
  • The indication for the test and the formulation of the question for self-testing are quite vague because investigations and treatment should be sought based on symptoms, and CRP can be reliably defined in that context.

PSA test

  • According to package inserts, two reviewed tests give positive results for PSA exceeding 4 ng/ml, and the limit given for the third test is 3 ng/ml (laboratories use μg/l as the unit). All the instructions suggest contacting a doctor if the result is positive.
  • Reproducibility and test characteristics are not described in more detail.
  • Negative results do not exclude and positive results do not show cancer; therefore, the recommendation to seek assessment by a professional is often appropriate.

HIV and syphilis tests

  • Antibodies showing HIV or syphilis infection can be demonstrated in a finger prick sample.
  • An HIV test is useful only when 3 months or more have passed since the situation involving a risk.
  • The two CE-marked tests available in Finland are reliable if performed correctly, but if the result is positive, the patient must have a test taken for confirmation and seek treatment.

Borreliosis test

  • The borreliosis test based on showing IgM antibodies is recommended to be done 2-6 weeks after the tick bite.
  • The diagnosis of borreliosis is challenging even in laboratory conditions and based on several phased investigations.
  • IgM antibody detection as such is probably of no use.

Urine tests

  • In urine tests, a test strip can be placed directly under the stream of urine or dipped in a collection vessel, or urine can be pipetted onto a cassette.

Hormones

  • As the concentrations of several hormones in urine correlate well with the concentrations in blood, urine is a good sample material for assessing hormone levels.
  • Blood tests sometimes give false positive results due to confounding antibodies in the patient's blood, but as antibodies do not usually occur in urine, determining hormone levels in urine is a good way of ensuring results free from confounding factors.
  • Close to detection limits, dilute urine may give negative results. Therefore, the significance of low or negative results must be assessed critically.
  • When determining hormone levels, bacterial contamination, for example, will not affect the results but the diluteness of urine will affect them significantly.
  • The sensitivity of pregnancy tests varies greatly, even in the range of 1-50 IU of human chorionic gonadotrophin (hCG) per litre (Henrik Alfthan, unpublished data).
    • The problem with these tests is not so much detecting pregnancy early enough, but as the tests may give positive results at very low concentrations, they may detect biochemical pregnancy with very early spontaneous abortion.
    • If urine is dilute, the results of pregnancy tests may in early pregnancy remain negative. However, in early pregnancy, hCG concentrations increase exponentially, doubling every few days; therefore, repeating a negative test a couple of days later, as necessary, will very soon give a positive result if the pregnancy develops normally.
    • Serum hormone tests will ultimately give a correct picture of the levels.
    • In any case, the urine hCG test is probably the most useful home test.
  • Ovulation tests measuring luteinizing hormone (LH) levels can be used to assess the time of ovulation by doing tests daily until reaching the peak.
    • As LH and hCG are very similar dimers, hCG may give a positive result in the LH test and vice versa.
  • In the so-called menopause test, 25 IU/l is specified as the limit for positive levels of follicle-stimulating hormone (FSH) but a single measurement cannot confirm the situation. The test is therefore recommended to be repeated several times every 1-2 weeks. Permanently positive results suggest menopause.

Infections

  • In microbiological tests for sexually transmitted diseases (chlamydia, gonorrhoea), the laboratory urine sample should be obtained from the first part of the urine stream without having washed the genital area before the test.
    • There are self-tests available for testing chlamydia for both men and women, involving taking swab samples from the mucosa. Due to the sampling method alone, negative test results are probably quite uncertain.
  • To diagnose urinary tract infections, midstream urine is collected after washing the genitals.
    • The same strips can be used for chemical screening by self-testing as professionals use, but the results are read visually, not by a reflectance photometer, which may cause uncertainty in interpretation.
    • In chemical screening, a nitrite detection test is reliable in detecting the growth of gram-negative bacteria because a positive result requires incubation in the bladder. Contamination from the skin, for example, will therefore not disturb the test as it would in urine particle counting or bacterial culture.
    • The test can probably well be used together with a positive leukocyte detection test to show urinary tract infection.

Respiratory tract infections and microbial detection tests

  • There are point-of-care tests available for coronavirus and influenza viruses. The samples are taken from a nostril, the nasopharynx and pharynx or saliva.
  • The sensitivity of testing depends on the stage of the disease and on sample quality.
  • Antigen tests are usually reported to have a sensitivity of more than 90% and a specificity of at least 97% compared with nucleic acid detection (PCR).
  • The sensitivity of any individual self-test is difficult to specify because the result depends largely on the whole testing process from sampling to the performance of the test.
  • In microbial detection tests, poor samples usually give false negative results. Both false positive and false negative results are possible depending on the pretest probability of the disease, i.e. the epidemic situation and the symptoms.
  • In antigen tests, the best time for sampling is usually when the symptoms have just started and a lot of viruses are excreted onto the mucosa.
    • For swab samples, mucosal cells should be obtained, not just mucus.
    • Sampling from the mucosa and the nasopharynx is challenging, and false negative results are probably more likely to result from insufficient sample material than from a nonfunctional test.
    • If a person with symptoms gets a positive result from a microbial antigen detection test, the disease can probably be specified.
    • If the test remains negative, even the tested disease cannot be fully excluded.