A Cochrane review [Abstract] 1 included 27 studies with a total of 1512 subjects. 38 different implant types were compared with a follow up ranging from 1 to 10 years. All implants were made in commercially pure titanium and had different shapes and surface preparations. On a 'per patient' rather than 'per implant' basis no significant differences were observed between various implant types for implant failures. The only observed statistically significant difference for the primary objective regarded more peri-implant bone loss at Nobel Speedy Groovy implants when compared with NobelActive implants (MD -0.59 mm; 95% CI -0.74 to -0.44, different implant shapes). The only observed statistically significant difference for the secondary objective was that implants with turned (smoother) surfaces had a 20% reduction in risk to be affected by peri-implantitis than implants with rough surfaces three years after loading (RR 0.80; 95% CI 0.67 to 0.96). There was a tendency for implants with turned surfaces to fail early more often than implants with roughened surfaces.
Primary/Secondary Keywords