2. If fluctuation (tidaling) in the water-seal compartment of a closed chest drainage system has stopped, a nurse should:

Choices

Choices ⬆ ⬇

1. Increase wall suction above 20 cm H2O pressure.

2. Raise the apparatus above the chest to move the fluid.

3. Ask the client to cough and deep breathe.

4. Vigorously strip the tube to dislodge the clot.

Question  Hint

Hints ⬆ ⬇

Test-Taking Tip

Remember that the water seal fluctuates with changes in the intrathoracic pressure from breathing.

Content Area: Adult Health, Respiratory; Integrated Process: Nursing Process, Implementation; Cognitive Level: Application; Client Need/Subneed: Physiological Integrity/Reduction of Risk Potential/Potential for Complications of Diagnostic Tests/Treatments/Procedures

Go to Choices

Rationale ⬆

Reduction of Risk Potential

leftnavigator11 home rgtnavigator11

3.  

Answer 1 is incorrect because the level of wall suction does not affect the water seal. This pressure enhances drainage. Answer 2 is incorrect because closed chest drainage should always remain below the level of the heart. Answer 3 is correct because this will change the intrapleural pressure and reestablish suctioning. Answer 4 is incorrect because stripping a chest tube may cause trauma to the lung.